28 SRV62_66
4.2 Trouble Shooting
Failure Possible Cause Remedy Remarks
Tamper does not start
Mistake in operating the unit
Perform the start procedure as
described
# 2.5
Lack of fuel Check the fuel level # 2.4.1
Dirty air filter Clean/replace the air filter # 3.3.2
Dirty fuel filter Replace the fuel filter # 3.3.3
Dirty spark plug
Clean, adjust, replace the spark
plug
# 3.3.4
Fuel line mounted incorrectly Check the assembly of the fuel line
Dirty air filter Clean, replace the air filter # 3.3.2
Dirty fuel filter Replace the fuel filter
# 3.3.3
Dirty spark plug
Clean, adjust, replace the spark
plug
# 3.3.4
Fuel cock closed Open the fuel cock
Defective centrifugal clutch Repair
Irregular compaction
Tamping shoe worn Replace the tamping shoe # 3.3.6
Engine runs but does
not reach full speed or
engine runs but stops
after a short period
Engine runs at full
speed, tamper does
not work or works
insufficiently
Authorized
service
personnel only