SRV62_66 29
5 Preserving the Machine
5.1 Preservation Measures
5.2 Removing Machine Preservatives
If the tamper is planned to be put out of operation for an extended period of time (approx. 1 ... 6 months), e. g.
during the winter season, it must be stored in a frost-proof and dry room. Before storing the machine, however,
the preservation measures described in paragraph 5.1 must be taken. After the storage, the tamper must be put
in operation according to paragraph 5.2.
If the tamper is to be stored for more than 6 months, additional measures must be taken in accordance
with your WEBER service.
Assembly Group Measures Remarks
Whole tamper
- Thoroughly clean
- Perform pre-start work # 2.4
Assembly Group Measures Remarks
Whole tamper
- Check condition, fastenings and tightness
- Thoroughly clean
- If required, have the failures ascertained repaired
Engine
- Check the oil level, add oil, if required # 2.4.2
-
In the place of storage, put the tamper into
operation and let it run until the operating
temperature is reached
- Put the tamper out of operation # 2.7
- Obturate all openings
Fuel tank
- Add fuel up to the bottom edge of the filler neck # 2.4.1
All bare parts
- Apply a slight film of grease or oil