Diagnostics
Monitoring operation
You can monitor the system operation of your LINK 740 by looking at the green system LED and referring to
the table below.
Important: The LINK 740 device must be activated in WEBFLEET.
GREEN LED mode
OFF Unit is in standby mode or is not connected to power.
•
Switch on ignition.
•
Check if the device is properly connected to power.
OFF and short ON every 3sec Ignition off.
Flashing No operating system and/or no application available or appli-
cation failed.
•
Contact the Webfleet Solutions support team at
www.webfleet.com/support.
Rapidly flashing (YELLOW LED is OFF) Reset to factory settings
ON and short OFF every 3sec Ignition on. Application is running, device is not activated.
•
Activate device.
ON Application is running, device is activated.
You can monitor the connection of your LINK 740 to the mobile network by looking at the yellow connec-
tion LED and referring to the table below.
YELLOW LED mode
OFF Not connected - No mobile network coverage.
•
Check if device is connected to power. Switch on ignition.
•
Move the vehicle as you may be in a mobile network
dead spot.
OFF and short ON every 3sec Not connected - Correct mobile network operator not
avaialable.
•
Check contract for mobile network roaming support.
•
Move the vehicle as you may be in a mobile network
dead spot.
Flashing SIM not in place; SIM defective; Modem problem.
•
In case of SIM modem issues, please contact the Webfleet
Solutions customer support at www.webfleet.com/sup-
port.
22