12 | W21 Magnet Drive System
®
Quick Guide
E.TE2
Motor
rotation
detection
fault
Detect when motor is
running.
Detect with load.
Detection overtime
Capacitance difference is
too big between motor and
inverter.
Motor parameter setting
mistake.
Detect after motor stops totally.
Re-detect without load.
Check motor connection wire.
Change inverter model.
Reset parameter according to na-
meplate.
E.EEP
Storage
failure
Electromagnetic disturb in
storage period.
EEPROM damage.
Resume load and save.
Seek support from vendor.
LIFE Reserved
Seek support from vendor.
E.ILF
Input side
open pha-
se
3-phase input power open
phase.
Check 3-phase power supply and
the phase.
Check 3-phase power supply wi-
ring.
E.oLF
Output
side open
phase
3-phase output power
open phase
Check 3-phase output voltage
and current.
Check wiring.
E.Gnd
Output
earth
Output earth terminal short
circuit.
Check wiring and insulation.
E.HAL
Current
detection
fault
Detect circuit fault.
Phase imbalance
Seek for technical support.
Check motor and wiring.
E. EF
Inverter
external
fault
Peripheral equipment fault
protection.
Check peripheral equipment.
E.PAn
Keyboard
connect
fault
Keyboard wire fault.
Keyboard component
damage.
Check keyboard wire.
Seek support from vendor.
E. CE
Rs-
485com-
munication
fault
Unsuitable baud rate set-
ting.
Communication wire bre-
aks.
Communication format
does not match upper
machine.
Set suitable baud rate setting.
Check communication wire.
Set right communication format.
E.CPE
Parameter
copy fault
Parameter copy communi-
cation is fault.
Copy keyboard is not
match the inverter.
Check wire.
Select the specified external key-
board model.