EasyManua.ls Logo

WEG W21 - 3 - Inverter installation and connections; Standard Connection Diagram

WEG W21
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 | W21 Magnet Drive System
®
Quick Guide
Standard Connection Diagram
●
Standard Connection Diagram
notice2
notice:defaultsettingsinbracket
notice1
TA1
TB1
TC1
+24V
Y
shieldedtwistedpaircable
_
mA
2
0
10
0
-
+
0
5
1
0
V
_
+
-
GND
A01
V
W
U
M
~
shieldedcables
(nearinvertergroud)
E
(groundresistorlow
than10
)
W
V
U
outputrea ctor
DCreactor
brake
resistor
short
circuit
P1
+
( )
R
brakemodule
voltagemodelanaloginput
currentmodelanaloginput
+10V
R
T
S
ACinput
AI
GND
AS
VS
shieldedtwistedpairline)
inputpulse
X7
(reversaljogrunning)
(forwardjogrunning)
(reversalrunning)
(forwardrunning)
(freestop)
(faultreset)
(none)
COM
X3
X4
X6
X5
X1
X2
PB
( )
+
(-)
inverter
S
T
R
GND
A02
COM
AC220V
AC0V
K3
K4
maxoutput
3A/240VAC
5A/30VDC
1+24Vmax output
:
DC24V/100mA
A01/A02 used as frequency or
voltage output
,maxcurrent
2mA
2VS/AIterminal resistor
:
75K
1.+10V terminals max input 50mA
notice:
2Y max output
:
DC24V/50mA
notice
2
standforcontrolcircuitterminal
notice
standformaincircuitterminal
1
shieldedtwistedpair
cable(nearinverterground)
inputreactorconnector
circuit
breaker
0~5V
)/
0~10V
)
0~20mA
)/
4~20mA
)
3 AS terminal resistor
:
250
notice
+
( )
notice4
PUL
X7
PUL
+24V
PLC
COM
current/voltageanaloginput
J1
J2
J3
K1
K2
K5
K6
TA2
TB2
TC2
AC220V
AC0V
A+
B-
RS485communication
120
K7
K8
analogoutputmonitor
3 - Inverter installation and connections
Read the WEGPM User’s Manual which is supplied with the inverter before installing, powering up or
operating the inverter.
F
Note!
g
Install the inverter according to Chapter 3 - Installation and connections of the Manual.
g
Prepare the drive and power up the inverter according to Chapter 4 - configuration of the inverter of the
Manual.
Note:
1.When installing DC reactor, make sure to dismantle the short connector between terminal P1 and (+).
2.NPN or PNP transistor signal can be selected as input of multi-function input terminal (X1~X7/PUL). Inverter built-in power supply
(+24V terminal) or external power supply (PLC terminal) can be chosen as bias voltage. Factory setting ‘+24V’ short connect with ‘PLC’.
3. Analog monitor output is the special output for meters such as frequency meter, current meter and voltage meter. It can’t be used for
control operations such as feedback control.
4. As there are multi pulse styles, please refer to the line connect mode description details.

Other manuals for WEG W21

Related product manuals