3.4.2 Do Clearing
This operation is used to clear current workpiece coordinate of each axis and set the
machine coordinate of each axis to the workpiece offset. As a result, the workpiece
origin turns to zero.
To do clearing, do the following:
1. To enter into Coor-Auto interface, press A.
2. Press F6, and select the target axis to do clearing:
F1: to clear the workpiece coordinates of X-axis.
F2: to clear the workpiece coordinates of Y-axis.
F3: to clear the workpiece coordinates of X-axis and Y-axis.
F4: to clear the workpiece coordinates of Z-axis.
F5: to clear the workpiece coordinates of all axes.
3.4.3 Execute Mobile Calibration
This operation is used to set the workpiece origin of Z-axis by executing calibration
at the current position.
Before executing mobile calibration, do the following:
1. Return to the machine origin.
2. Set the value of parameter Mobile Presetter Thickness:
1. Manually move Z-axis to a certain point over workpiece surface, shift
down the tool nose until reaching the workpiece surface, and record the
current coordinate of Z-axis (Z1).
2. Uplift Z-axis, put a tool presetter on the workpiece surface, shift down Z-
axis slowly until reaching the presetter and getting the tool presetter
signal, and record the current coordinate of Z-axis (Z2).
3. Get the result of Z2-axis minus Z1-axis, and set it as the value of
parameter Mobile Presetter Thickness.