ER12D-1
Revision 01.0 170620
COMPLIANCE AND WARRANTY INFORMATION
This appliance must be installed by a registered electrician in accordance with the relevant electrical
wiring rules and regulations and a COC is required for a warranty claim.
Heat Transfer units are Not for use with a heat pump
Do not cover the fan unit with any insulation material
Do not completely close off adjustable outlet vents
Always install this product with the supplied controller
Weiss Limited reserves the right to alter designs and specifications without notice
Incorrect wiring or installation is not covered by warranty
Full Warranty information is available on our web site: https://www.weiss.co.nz/warranty
QUESTIONS AND ANSWERS
Can I place the controller in a different room from the fireplace/heat source?
No. The controller must be mounted in the same room as your heat source. Make sure that the controller is
in a position where it can easily detect changes in the room temperature from your heat source, e.g. 2-4
metres away from the heat source. Do not place the controller in the hallway or near the doorway, around
a corner from the heat source, or far away (>6 metres) from the heat source in a large room.
How far away from the heat source should I place the fan?
You should keep at least 1.5 metres of distance between the heat source extraction point and the fan.
However, the recommended distance between the extraction point and the fan is 3 metres.
IMPORTANT NOTES
Troubleshooting: The control panel has built-in error detection and may display the following faults:
Sensor fault will display and“E1”and“E2”.
E1: Sensor short circuit alarm
E2: Sensor open circuit alarm
When temperature higher than 55 displays HI
When temperature lower than 0 displays LO
Technical Specifications
Set Temperature Range: 5 - 35°C
Temperature Resolution: 0.5°C
Operating Voltage/Frequency: 220V 50/60Hz
Sensing Element: NTC
Operating Temperature: 0 to 50ºC
Approval: All relevant AS/NZS standards
EMC Approval: All relevant AS/NZS standards
The unit should be checked annually for correct operation.
This controller has been designed to work with Weiss Heat Transfer AC Fans only.