MANUAL
ELECTRICAL SYSTEM DOCUMENTATION
ROTARY INDEXING TABLE CONTROLER
EN_06_2016
EF2

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the WEISS EF2300B and is the answer not in the manual?

WEISS EF2300B Specifications

General IconGeneral
BrandWEISS
ModelEF2300B
CategoryController
LanguageEnglish

Summary

2 SAFETY

2.1 Basic safety instructions

Outlines general safety principles, operator duties, and technical safety measures.

2.2 Emergency Stop Circuit

Details the necessity of an emergency stop circuit for immediate shutdown and safe operation.

3 COMPONENT DESCRIPTIONS

3.1 Power Modules PM240-2

Describes the features, design, and technical data of the PM240-2 power modules.

3.4 Safety relay

Explains the safety relay type, features, and its role in safety functions with technical data.

3.7 SIMOTION D410-2 Control Unit

Describes the SIMOTION D410-2 control unit, its interfaces, and technical data.

4 FUNCTION AND SIGNAL DESCRIPTIONS

4.5 Interface assignment D410-2

Details the pin assignments and descriptions for the SIMOTION D410-2 interfaces.

5 SAFETY FUNCTIONS

5.1 Integrated safety functions (SIL2)

Describes the built-in safety functions compliant with SIL2 standards like STO.

5.2 Extended safety functions (SIL3)

Explains how to achieve SIL3 compliance using additional measures like safety relays.

6 INSTALLATION

6.2 Power Module PM240-2; frame size FSA / FSB

Details the proper mounting, dimensions, and connections for PM240-2 power modules.

6.6 SIMOTION D410-2 Control Unit

Covers the mounting, disassembly, and CF card insertion for the control unit.

7 EF2 - PC CONNECTION

8 OPERATION / DESCRIPTION OF WEISS SOFTWARE

8.3 Machine configuration

Details the steps for configuring the rotary indexing table, including indexer and I/O setup.

8.5 Operation and Monitoring

Describes how to monitor I/O, use manual operation, and view system messages.

10 COMMUNICATION WITH A HIGHER-LEVEL CONTROLLER

10.1 Profibus DP

Details the connection procedure for Profibus DP communication with a SIMOTION D410-2.

10.2 Profinet IO RT

Explains the connection procedure for Profinet IO RT communication with a SIMOTION D410-2.

11 DIAGNOSTICS

11.3 Error messages

Provides a comprehensive table of error codes, causes, and recommended remedies for troubleshooting.