26 Part Number 000016034 Rev 00 07/19
Maintenance Section 4
Step 10 Refer to Removal of Parts for Cleaning/Sanitizing
and disassemble parts for hand cleaning/sanitizing.
• Hand clean all parts.
• Rinse all parts with clear potable water.
• Sanitize all parts — do not rinse after sanitizing.
• Spray all interior bin surfaces with sanitizer (do not rinse
sanitized areas).
• Spray evaporator discharge spout.
Step 11 Reassemble ice machine.
Step 12 Turn off the ice making water supply.
Step 13 Refer to chart and premix water and sanitizer.
Amount of Water Amount of Sanitizer
4 L Water 15 ml
Step 14 Fill the evaporator and reservoir with sanitizer/
water solution.
Step 15 Move the toggle switch to the ON position. The
ice machine will make ice with the sanitizer/water solution
and deposit the ice in the bin. Add the remaining sanitizer/
water solution when the water level in the reservoir drops.
NOTE: Do not allow the sanitizer/water level to drop below
the minimum water level. The ice machine will discontinue
the cleaning cycle if the water float switch opens.
Step 16 After all of the sanitizer/water solution has been
added to the reservoir, turn on the ice making water supply.
Step 17 Continue the freeze cycle for 30 minutes and then
discard all ice produced.
Procedure to Clean Heavily Scaled Flake Ice
Machines
Step 1 Remove front and top covers and set the toggle
switch to the OFF position.
Step 2 Remove all ice from the bin.
Step 3 Turn off the ice making water supply.
Step 4 Remove the top cover from water reservoir.
Step 5 Refer to chart below:
Premix cleaner with lukewarm water in a non-metallic
container.
Model
Water Reservoir
Capacity
Mix Cleaner and Water
Use Metal Safe Ice Machine
Cleaner, part number 000000084
only
Cleaner Water
UF0244
UN0200
UF0200
UF0350
UN0300
UF0388
UF0399
400 ml 266 ml 148 ml
RF0320
RN320
RF0620
RN0620
500 ml 325 ml 177 ml
RN1100
RF1300
RF1220
1 L 680 ml 325 ml
RF2500
RF2200
2 L 1.3 L 650 ml
Step 6 Remove all water from the evaporator and water
reservoir. Add the entire cleaner/water solution and re-
install the reservoir cover.
Leave the cleaner/water solution in the evaporator for a
minimum of 4 hours.
Step 7 Remove all cleaner/water from the evaporator
and water reservoir.
Step 8 Follow the standard cleaning and sanitizing
procedures.