7
Refer to the nameplate on the front of the appliance.
• Verify the ELECTRICAL SERVICE POWER.
• Voltage and phase must match the nameplate specifications, and
available electrical service amperage must meet or exceed the
specifications listed on page 1.
• Wiring must be no less than 4 AWG 4 conductor solid copper wire,
rated for at least 90ºC.
NOTE: Wire gauge, insulation type and temperature rating , as well as
type, size and construction of conduit, must meet or exceed applicable
specifications of local codes and of the National Electrical Code.
This appliance is equipped with a Hubbell™ L430P9 plug, which must
be plugged into a matching Hubbell™ L430R9 receptacle. The ground
lug of the receptacle must be connected to a suitable building ground.
IMPORTANT:
The appliance is shipped from the factory wired for 3-phase (3ø)
electrical service. This appliance is not approved for 1ø operation.
Conversion of this appliance to single-phase operation will void the
warranty.
IMPORTANT PROGRAMMING NOTE:
This oven is pre-programmed from the factory and normally does not
require programming adjustments.
CAUTION:
Risk of
Damage
DO NOT connect or energize
this appliance until all in-
stallation instructions are read
and followed. Damage to the
appliance will result if these
instructions are not followed.
CAUTION:
Electrical Shock
Hazard
The ground lug of this
appliance must be connected
to a suitable building ground.
IMPORTANT:
Contact a licensed electrician
to install and connect
electrical power to the
appliance.
IMPORTANT:
Damage due to being
connected to the wrong
voltage or phase is NOT
covered by warranty.
INSTALLATION (continued)
DANGER: ELECTRICAL SHOCK HAZARD
ELECTRICAL CONNECTIONS MUST BE MADE BY A
LICENSED ELECTRICIAN
Electrical shock will cause death or serious injury.