TROUBLESHOOTING SUGGESTIONS
10
SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY
No power to warmer Circuit breaker off or tripped Reset circuit breaker
Warmer will not heat Temperature control not set Set control to desired temperature
Warmer trips circuit breaker
Wet insulation
Verify flange-to counter seal is
sound, or reseal with food-grade
silicone sealant
Pan leaking or other internal damage
Contact your Authorized Wells
Service Agency for repairs
Internal damage
Contact your Authorized Wells
Service Agency for repairs
Warmer slow to heat
Mineral deposits on pan acting as a
insulator
Clean pan(s) with delime cleaner
Wired to wrong voltage
Verify supply voltage - must match
voltage on warmer nameplate
Drain valve not fully closed
Check drain valve for debris and
close fully
Drain valve damaged or pan(s)
leaking
Contact your Authorized Wells
Service Agency for repairs
Drain-equipped unit will not hold
water
There are no user-serviceable components in this appliance.
In all instances of damage or malfunction, contact your Authorized Wells Service Agency for repairs.
WIRING DIAGRAM
M012C.04 2M-308032 Owners Manual for Four-Well Inf.Sw. MOD-Warmers