PREVENTATIVE MAINTENANCE
A. Open filter enclosure. Press this tab on both sides of the enclosure to remove the lid.
B. Locate and remove the sediment and pre carbon filters. Connect to a water supply and flush for 3 minutes into a bucket.
C. Locate and remove the Bio-Sure Plus filter. Connect to a water supply and flush into a bucket for 3 minutes.
D. Locate and remove the TCR filter. Connect to a water supply and Flush the backwards into a bucket for 3 minutes.
E. Turn water off and return filters and tubing to their original locations.
F. Let the RO flush into a bucket for 30 minutes, then reconnect the product water tube to the ice machine.
Filter Change Regime:
Pre-Sediment Filter (HF-EX1(P)) 1 year
Pre-Carbon filter (HF-EX2(P)) 1 year
Reverse Osmosis (HF-EX3R(P)) 2- 3 years
Bio-Sure Plus RO (HF-EX4R(P)) 1 year
TCR (HF-EX5(P)) 2 years