OPERATION
WARNING: Read and thoroughly understand all instructions and safety information before op-
erating this log splitter. Failure to do so may cause serious injury or death. Do not allow anyone to
operate this log splitter who has not read this manual. As with all power equipment, a log splitter can
be dangerous if assembled or used improperly. Do not operate this log splitter if you have doubts or questions
concerning safe operation. Call our customer service department at 1-800-232-1195 to address these concerns.
WARNING: Always wear safety glasses, safety gloves, safety shoes and suitable work clothing when
operating this log splitter. Do not wear jewelry, neckties or other loose clothing which could get
caught in moving parts.
WARNING: Keep hands and feet clear of the ram and wedge at all times.
WARNING: Do not start or operate this machine in the presence of flammable liquids or gases.
Before operating, select a suitable work area and check the level of hydraulic fluid.
A safe work area will contain a flat surface on which to place the log splitter, as well as ample room to stack both
split and unsplit logs. Make sure there is a safe electrical connection no more than 25 feet from the workspace.
WARNING: Lifting the log splitter is a two person operation. Once raised, make sure the log split-
ter is stable before performing any maintenance. 2
To check the level of hydraulic fluid:
1. Lift up on the handle of the Log Splitter. Make certain the Log Splitter
is stable and will not fall.
2. Loosen the fluid drain knob (1).
3. Pull out the bolt with attached dipstick and wipe the dipstick.
4. Put the dipstick back in the tank and pull it out again.
5. Check the fluid level on the dipstick. It should be between the two
notches on the end of the dipstick (2).
6. Add fluid if needed. Replace dipstick and tighten the fluid drain knob.
Remember to use AW32 fluid for operation at temperatures above 40 degrees Farenheit, and Dexron® automat-
ic transmission fluid for operation below 40 degrees Farenheit. The Log Splitter is pre-loaded with AW32 fluid