What to do if my Westinghouse WGen2000 Portable Generator has no electrical output?
- JJacob ArmstrongAug 3, 2025
If your Westinghouse Portable Generator's engine is running but there's no electrical output, consider the following: 1. The circuit breakers might be tripped. Reset them and check for an overload condition. 2. The power cord’s plug connector may not be fully engaged in the generator’s outlet. Verify it is firmly engaged. If using the 240V outlet, ensure the plug connector is rotated 1/4 turn clockwise. 3. The power cord could be faulty or defective. Replace the power cord. 4. The electrical appliance you're using might be faulty or defective. Try connecting a known good appliance to verify the generator is producing electrical power. 5. The GFCI outlet may be tripped. Press the reset button on the GFCI outlet.