WFCO EM-15 - EM-15; EM-20 Troubleshooting Guide

WFCO EM-15
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
Symptom Potential Reason Action to Perform
No power on both circuits. 1. No power to EM-##
2. EM-## is in OFF-time
delay”
1. Verify that the RV has
power & reset the EM-##
breaker
2. Power the EM-## for 5
minutes & verify operation
No power on one circuit
(the other circuit is OK).
1. Load may not be turned
ON
2. EM-## may have turned
o 1 circuit because of
current draw
3. EM-## may be in “OFF-
time delay”
1. Turn ON both loads
2. Turn OFF power to the
operating circuit appliance,
wait 5 minutes & verify
operation of the other
circuit appliance
3. Power the EM-## for 5
minutes & verify operation
Both circuits are on at the
same time.
1. Total current draw may
be below the trip point
2. EM-## may be in the
wrong mode
1. Turn both appliances
on high & verify that the
circuit breaker doesn’t trip
2. Refer to qualied service
technician for mode
verication
No LED lights on the
remote.
1. No power to EM-##
2. Bad connection on the
remote cable
3. Defective remote
1. Verify that the RV has
power & reset EM-##
breaker
2. Replace remote cable
3. Replace remote
Switch doesnt work on the
remote.
1. EM-## may be in “OFF-
time delay”
2. Defective remote
1. Power the EM-## for 5
minutes & verify operation
2. Replace remote
Refer to the Troubleshooting Chart on the next page.
e air conditioner logic wiring chart assumes the air conditioner expects a relay contact
closure when the compressor should be o. Please refer to the air conditioner
manufacturers manual for more information.
EM-15 / EM-20 TROUBLESHOOTING