6. Troubleshooting - Whale iVan Control Panel
Step 1 - Space Heater Lockout
Step 2 - Identify Lockout Step 3 - Recommended Action
Example Fault type #1 - Inadequate gas supply
1. Check gas
2. 30mbar LPG
3. Go to step 4
Fault type #2 - Overheat
1. Check air vents and ducts are not restricted
2. Wait 10 mins for heater to cool down
3. Go to step 4
Fault type #3 - Inadequate supply voltage
10.5 - 15.9V d.c. - Heater inoperable under 10.1V
≥ 10.5 / ≤ 15.9V d.c.
< 10.5 / >15.9V d.c.
Go to step 4
Fault type #4 - Flue blockage
1. Check fl ues for blockages
2. Go to step 4
Example Fault types #5-11 Internal fault
1. Go to step 4
2. Call Whale support +44 (0)345 9090 911.
Fault type #15 - Multiple faults
1. Power off
2. Check heater for recurring faults
3. Power on
4. Go to step 4