3 - TECHNICAL DATA
0812_GB_42 - GAS KITCHENS
6 · 16
04/2008
Primary air distance “A” mm
Methane gas G20
Liquid gas G30/G31
Category
Construction type
Air necessary for combustion
Nominal thermal power
Minimum thermal power
Overall thermal power (gas)
Model
Connection pressure
Methane gas 2H
Liquid gas 3+
Gas connection values
Methane gas 2H
Liquid gas 3+
Nozzles Ø 1/100 mm
Main burner
G20
G30/G31
(HuB = 9.45 kWh/m
3
) in m
3
/h
(HuB = 12.87 kWh/kg) in kg/h
Nominal thermal power
Minimal thermal capacity
Nominal thermal power
Minimal thermal capacity
G20
G30/G31
20 mbar
28/37 mbar
18.4
25.8
kW
kW
II2H3+
A
m
3
/h
kW
kW
No. of nozzles pilot burner
G20
G30/G31
8
3
C
Ø 100
7
3.7
0.85
0.370
0.272
145
Adjustable
95
40
-
-
1,95
2,73
-
-
1,44
2,02
Hour consumption
G20
m
3
/h
G25
m
3
/h
G30/G31
kg/h
ADN 604
ADN 605
Gas oven
GN 1/1
7.5
3.6
0.95
Open
Open
0.381
0.284
145
Adjustable
95
50
-
-
TABLE 1