Level Range
1. Place level on the oven bottom, as indicated in one of the two
figures below, depending on the size of the level. Check with
the level side to side and front to back.
2. If range is not level, use a wrench or pliers to adjust leveling
legs up or down until the range is level.
NOTE: Range must be level for satisfactory baking
performance and best cleaning results using AquaLift
®
Self-Clean Technology.
Electrical Connection - U.S.A. Only
Power Supply Cord
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
1. Disconnect power.
2. Remove the terminal block cover screws located on the back
of the range. Pull cover down and toward you to remove cover
from range.
A
B
C
A. Mounting tabs (3)
B. Lower access cover
C. Screws
3. Remove the three 10-32 hex nuts from the terminal posts.
A
C
B
A. 10-32 hex nuts
B. Terminal Posts
C. Ground-link strap
4. Add strain relief.
Style 1: Power supply cord strain relief
Remove the knockout for the power supply cord.
Assemble a UL listed strain relief in the opening.
A
A. UL listed strain relief
Tighten strain relief screw against the power supply cord.