Installation Instructions for
Heating & Air Conditioning
IF78
Non-Programmable Thermostat
CONTENTS
Preparations .................................................. 1
Thermostat Details ........................................ 1
Removing Old Thermostat ............................ 1
Mounting and Wiring ..................................... 2
Check Thermostat Operation ........................ 3
Specifications ................................................ 5
Troubleshooting ............................................ 5
PREPARATIONS
THERMOSTAT DETAILS
REMOVING OLD THERMOSTAT
Before removing wires from old thermostat’s switching subbase,
label each wire with the terminal designation it was removed from.
1. Remove Old Thermostat: A standard heat/cool thermostat
consists of three basic parts:
a. The cover, which may be either a snap-on or hinge type.
b. The base, which is removed by loosening all captive screws.
c. The switching subbase, which is removed by unscrewing
the mounting screws that hold it on the wall or adaptor plate.
2. Shut off electricity at the main fuse box until installation is
complete. Ensure that electrical power is disconnected.
3. Remove the front cover of the old thermostat. With wires still
attached, remove wall plate from the wall. If the old thermostat
has a wall mounting plate, remove the thermostat and the wall
mounting plate as an assembly.
4. Identify each wire attached to the old thermostat using the
labels enclosed with the new thermostat.
5. Disconnect the wires from the old thermostat one at a time. DO
NOT LET WIRES FALL BACK INTO THE WALL.
6. Install new thermostat using the following procedures.
To prevent electrical shock and/or equipment damage,
disconnect electrical power to the system at the main
fuse or circuit breaker until installation is complete.
CAUTION
!
Printed in U.S.A.
PART NO. 37-6194A
0106
WHITE-RODGERS
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
www.white-rodgers.com
Failure to follow and read all instructions carefully
before installing or operating this control could cause
personal injury and/or property damage
Assemble tools required as shown below.
YOUR THERMOSTAT REPLACES
1
2
3
WIRE CUTTER/STRIPPER
Typical System Combatibility Chart 620
Standard Heat Only Two Wire Gas or Oil Fired Systems (24 volt) Yes
Electronic Ignition Heat Only Two Wire Systems (24 volt) Yes
Electronic Ignition Heat Only Gas or Oil Fired Systems (24 volt) Yes
Standard Heat/Cool Systems (24 volt) Yes
Heat/Cool Systems Electric Heat (24 volt) Yes
Heat Only Electric Heat Systems (24 volt) Yes
Cool Only Systems (24 volt) Yes
Heat Pump Systems (No Aux or Emergency Heat) Yes
Hot Water Zone Heat Only (Two Wire) Systems Yes
Hot Water Zone Heat Only (Three Wire) Systems No
Line Voltage Heating or Baseboard 110/240 Volt Systems No
Millivolt Systems Floor or Wall Furnaces Yes
12 VDC Mobile Home Application Yes
Multistage Systems No
Systems Exceding 30VAC, 1.5 Amp No
W
RH
B RC
G
O
Y
+
-
+
-
GAS
ELE
C
W904
W905
Figure 1. Thermostat base
Mounting
hole
Mounting
hole
W905
Clip for
Hydronic
System
W904
Clip for
Celsius Display
Electric/Gas
Switch
HAND OR POWER
DRILL WITH 3/16 INCH
DRILL BIT, IF NEEDED
FLAT BLADE SCREWDRIVER
SPIRIT LEVEL OR PLUMB BOB AND LINE OPTIONAL—
THERMOSTAT DOES NOT NEED TO BE LEVEL TO WORK PROPERLY

Questions and Answers

  • S
    silvawilliamAug 2, 2025
    Why is my White Rodgers IF78 Thermostat not heating, cooling, or running the fan?
    • B
      blakemarioAug 2, 2025
      If your White Rodgers Thermostat isn't heating, cooling, or running the fan, here's what to check: * A blown fuse or tripped circuit breaker could be the culprit. Replace the fuse or reset the breaker. * Make sure the furnace power switch is turned to the 'ON' position. * Ensure the furnace blower compartment door or panel is correctly installed, engaging the safety interlock or door switch.
  • R
    rachel70Aug 11, 2025
    What to do if my White Rodgers IF78 isn't cooling?
    • B
      bergnicoleAug 11, 2025
      If your White Rodgers Thermostat isn't cooling, make sure the System Switch is set to 'Cool' and the temperature is set lower than the current room temperature. Also, verify that the thermostat and system wires are securely attached. If the issue persists, it may require professional service or thermostat replacement, following the same diagnostic procedure as for a 'No Heat' condition but ensuring the thermostat is set to 'Cool' and the setpoint is below room temperature.
  • L
    Laura EricksonAug 22, 2025
    How to fix a White Rodgers Thermostat that is not heating?
    • S
      Sherri MartinezAug 22, 2025
      If your White Rodgers Thermostat isn't heating, check the following: 1. Ensure the pilot light is lit. 2. Verify the System Switch is set to 'Heat' and the temperature is set higher than the current room temperature. 3. Confirm that all connections to the thermostat and system are secure. 4. If the heat works intermittently, this could indicate a furnace lock-out condition, and you should contact the furnace manufacturer or a local service person for assistance. 5. If the thermostat does not click after being reset it may require service or replacement, contact your heating and cooling service person or place of purchase for a replacement.

Summary

Preparations

Thermostat Details

Removing Old Thermostat

Mounting and Wiring

Electric Heat or Single-Stage Heat Pump Systems

Configuration for electric heat or single-stage heat pump systems.

Hydronic (Hot Water or Steam) Heating Systems

Configuration for hydronic heating systems (hot water or steam).

Battery Location

Location and replacement of batteries for thermostat operation.

Check Thermostat Operation

Fan Operation

Procedure to test the fan operation of the thermostat.

Cooling System

Steps to test the cooling system operation after installation.

Heating System

Steps to test the heating system operation after installation.

Specifications

Troubleshooting

Reset Operation

Procedure to reset the thermostat for operational issues.

No Heat;No Cool;No Fan (common problems)

Addresses common issues of no heat, no cool, or no fan operation.

No Heat

Troubleshoots and provides corrective actions for no heat issues.

No Cool

Troubleshoots and provides corrective actions for no cool issues.

Heat, Cool or Fan Runs Constantly

Addresses issues where heat, cool, or fan runs constantly.

Furnace Cycles Too Fast or Too Slow (narrow or wide temperature swing)

Troubleshooting furnace cycling rates and temperature swings.

Cooling Cycles Too Fast or Too Slow (narrow or wide temperature swing)

Troubleshooting cooling cycling rates and temperature swings.

Thermostat Setting and Thermostat Thermometer Disagree

Addresses discrepancies between thermostat settings and readings.

Blank Display and;or Keypad Not Responding

Troubleshoots blank displays or unresponsive keypads.