EasyManua.ls Logo

Williams 509622A User Manual

Williams 509622A
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
WARNING: If the information in these instructions
is not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
- Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Open all windows.
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone or cell phone in your building.
Extinguish any open flame.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach the gas supplier, call the fire
department.
Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
25,000 - 35,000
BTU/hr.
MONTEREY HOME FURNACE
TOP VENT GAS WALL HEATER
WARNING: Do not install any of these furnaces
(natural or propane gas) in mobile/manufactured homes,
trucks or recreational vehicles.
WARNING: This product can expose you to
chemicals including epichlorohydrin which is known to
the State of California to cause cancer and birth defects
and/or other reproductive harm. For information go to
www.p65warnings.ca.gov
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause injury or
property damage. Refer to this manual. For assistance or
for additional information consult a qualified installer or,
service agency.
SINGLE SIDED MODEL NUMBERS
(natural gas)
2509622A / 3509622A
(propane gas)
2509621A / 3509621A
DOUBLE SIDED MODEL NUMBERS:
(natural gas)
5009622A
(propane gas)
5009621A
DISCONTINUED MODEL NUMBERS:
2519622A  2539622A  2559622A  3519622A  3539622A
 355622A  5019622A  5039622A  5059622A  2519621A
 2539621A  2559621A  3519621A  3536221A  3559621A 
5019621A  5039621A  5059621A
SAVE THIS MANUAL FOR FUTURE REFERENCE.
READ THIS OWNER’S MANUAL CAREFULLY BEFORE YOU
INSTALL YOUR NEW WILLIAMS WALL FURNACE.
250 West Laurel Street, Colton CA 92324 • WWW.WFC-FC.COM • 1-888-444-1212
50,000 BTU/hr.
TM
OWNER’S MANUAL
INSTALLATION INSTRUCTIONS
VISITEZ NOTRE SITE WEB POUR LA VERSION FRANÇAISE DE CE MANUEL
VISITE NUESTRA PÁGINA WEB PARA LA VERSIÓN EN ESPAÑOL DE ESTE MANUAL
https://www.williamscomfortprod.com/products/furnaces/
Question and Answer IconNeed help?

Do you have a question about the Williams 509622A and is the answer not in the manual?

Williams 509622A Specifications

General IconGeneral
BrandWilliams
Model509622A
CategoryFurnace
LanguageEnglish

Summary

Warranty Information

Limited One-Year Warranty

Details the manufacturer's warranty for parts defective in material or workmanship within one year.

Limited Extended Warranty

Covers defects in combustion chambers for nine years following the one-year warranty period.

Warranty Limitations

Outlines restrictions on implied warranties and liability for consequential damages.

Duties of the Consumer

Specifies consumer responsibilities like professional installation and record keeping for warranty claims.

General Warranty Information

Covers general terms, service procedures, and consumer rights related to the warranty.

Safety Rules

General Safety Precautions

Essential safety rules for installation, operation, and maintenance, including warnings and prohibitions.

Introduction and Initial Setup

Carbon Monoxide Poisoning Hazard

Critical warning about CO poisoning and steps for safe venting system operation to prevent it.

Basic Materials and Tools Needed

Lists essential materials and tools required for furnace installation.

Optional Accessories

Describes available optional accessories that enhance furnace functionality or installation.

Installing Your Furnace

Minimum Clearances and Location

Specifies required clearances from walls, ceilings, and floors, and guidelines for furnace placement.

Thermostat Location Guidelines

Provides advice on selecting an optimal location for the thermostat to ensure accurate room temperature sensing.

Combustion and Ventilation Air Requirements

Details the critical need for adequate air supply for combustion and ventilation, and air starvation signals.

Furnace Air Supply for Confined Spaces

Explains air supply methods for furnaces installed in confined spaces, both from inside and outside the building.

Recessed Wall Mount Installation

Step-by-step instructions for installing the furnace recessed into a wall, including cutting and mounting.

Surface Mount Installation

Instructions for surface mounting the furnace using an optional accessory, ideal for remodeling.

Free Standing Accessory Installation

Details the assembly and installation of the free-standing accessory for surface mounting.

Rear Outlet Kit Installation (Optional)

Instructions for installing the optional rear outlet register for directing heat to an adjacent room.

Gas Supply and Piping

Covers gas supply requirements, pressures, and proper piping practices for safe connection.

Front Panel Installation

Steps for attaching the front panel and control door to the furnace assembly.

Thermostat Installation

Detailed instructions for installing both wall-mounted and face panel-mounted thermostats.

Wall-Mounted Thermostat Installation

Specific steps for installing a thermostat directly onto the wall.

Face Panel-Mounted Thermostat Installation

Steps for mounting a thermostat onto the furnace face panel.

Vent Installation

Venting Procedures and Requirements

Guidelines for proper vent installation, compliance with codes, and types of approved vent materials.

Start-Up Procedure

Checking Gas Input and Pressures

Procedures for verifying gas input and manifold pressures to ensure correct furnace operation.

Operating Your Furnace

Pilot Burner and Flame Characteristics

Guidance on checking the pilot burner, its flame appearance, and normal/abnormal burner flame characteristics.

Lighting the Pilot

Step-by-step instructions for safely lighting the pilot flame by hand.

What to Do If You Smell Gas

Emergency procedures for detecting a gas leak, emphasizing immediate action and contacting gas suppliers.

Operating Instructions

Comprehensive steps for safely starting up and operating the furnace after installation.

How to Care for Your Furnace

Annual Upkeep and Cleaning

Recommendations for annual maintenance checks and cleaning of furnace components.

Furnace Area and Airflow Maintenance

Guidelines for keeping the furnace area clear and ensuring proper combustion and ventilation airflow.

Cleaning Blower and Burner Components

Instructions for cleaning the blower fan and burner assembly to maintain efficiency and safety.

Installing Your Blower Accessory

Blower Accessory 2901 and 2907 Installation

Detailed steps for installing the 2901 and 2907 blower accessories, including electrical connections.

Installing Your Motorized Rear Outlet Accessory

Motorized Rear Outlet Register Installation

Procedures for installing the motorized rear outlet register to direct heat into an adjacent room.

Blower Settings and Operation

Information on selecting blower settings (ON/AUTO) for optimal operation and fan control.

Part Numbers for the 250 / 350 Models

Exploded View & Replacement Parts Chart

Control Assembly Replacement Parts 250 / 350 Models

Part Numbers for the 500 Models

Exploded View & Replacement Parts Chart

Control Assembly Replacement Parts 500 Models

Blower Accessory Model 2901 Parts

Blower Accessory Model 2907 Parts

Motorized Rear Outlet Replacement Parts

Troubleshooting Your Furnace

Hints and Information

What to Do If You Smell Gas

Emergency procedures for detecting a gas leak, emphasizing immediate action and contacting gas suppliers.

How to Order Repair Parts

Provides essential information required when ordering replacement parts for the furnace.

Installations in Massachusetts

Outlines specific installation requirements for Massachusetts, including carbon monoxide detectors.

Service Record

Related product manuals