If there are further grease deposits still remaining on the
condenser call your Service Provider to carry out a full
service.
Note: Non-compliance may invalidate your Warranty.
Top Mounted Cabinets (WBC/WBCF50)
The condensing unit and refrigeration equipment can be
accessed from above or in some cases behind. Remove
the screws in the top and bottom edge of the unit cover
and pull the unit cover away from the cabinet and
retaining clips.
Bottom Mounted Units (WBC/WBCF10-40)
Pull the unit cover away from the cabinet and retaining
clips.
EVAPORATOR/DRAINLINE
Inspect periodically to ensure drain hole is not blocked.
REPLACING THE GASKET
Damaged gaskets are easily
replaced. Simply pull out existing part
and push new gasket into channel
(gasket retainer) at centre and work
along, pushing gasket into channel.
Continue with additional three sides, pushing corners in
last.