Display Slow Down
The purpose of applying a “display slow down” is
to delay the real time temperature being displayed
on the controllers front control interface. This will
avoid rapid uctuations displayed when a door is
opened, or when the controller is “hunting” the
instantaneous temperature. This is achieved by
introducing a thermal mass simulation routine in
the software to simulate a thermal mass inside the
chiller. The parameter “SiM” (default to 3) is used,
and an example being a value of 100 simulates a 0.5
litre (0.1 Gallon) bottle of water.