TEMPERATURE PARAMETERS
TEMPERATURE PARAMETERS
The Williams range of Reach-In Blast Chillers has temperature parameters set as follows:
+90°C (194°F) / +3°C (37°F)
The Williams range fo Reach-In Blast Chiller Freezers has temperature parameters set as follows:
+90°C (194°F) / +3°C (37°F) and +90°C (194°F) / -18°C (0°F)
The Williams range of Modular Blast Chillers, Chiller Freezers and Freezers are designed to blast chill freeze
products:
WMBC +90°C (194°F) / +3°C (37°F) in 90 minutes or less
WMBCF +90°C (194°F) / +3°C (37°F) in 90 minutes or less
+90°C (194°F) / -18°C (0°F) in 240 minutes or less
WMBF +90°C (194°F) / -18°C (0°F) in 240 minutes or less
Also designed to hold product at the following temperatures:
WMBC +1°C (34°F) to +3°C (37°F)
WMBCF +1°C (34°F) to +3°C (37°F) - Blast Chill Cycle
-18°C (0°F) to -22°C (-8°F) - Blast Freezer Cycle
WMBF -18°C (0°F) to -22°C (-8°F) - Blast Freezer Cycle