EasyManuals Logo

Williams WBCF50 User Manual

Williams WBCF50
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
3
TEMPERATURE PARAMETERS
TEMPERATURE PARAMETERS
The Williams range of Reach-In Blast Chillers has temperature parameters set as follows:
+90°C (194°F) / +3°C (37°F)
The Williams range fo Reach-In Blast Chiller Freezers has temperature parameters set as follows:
+90°C (194°F) / +3°C (37°F) and +90°C (194°F) / -18°C (0°F)
The Williams range of Modular Blast Chillers, Chiller Freezers and Freezers are designed to blast chill freeze
products:
WMBC +90°C (194°F) / +3°C (37°F) in 90 minutes or less
WMBCF +90°C (194°F) / +3°C (37°F) in 90 minutes or less
+90°C (194°F) / -18°C (0°F) in 240 minutes or less
WMBF +90°C (194°F) / -18°C (0°F) in 240 minutes or less
Also designed to hold product at the following temperatures:
WMBC +1°C (34°F) to +3°C (37°F)
WMBCF +1°C (34°F) to +3°C (37°F) - Blast Chill Cycle
-18°C (0°F) to -22°C (-8°F) - Blast Freezer Cycle
WMBF -18°C (0°F) to -22°C (-8°F) - Blast Freezer Cycle

Other manuals for Williams WBCF50

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Williams WBCF50 and is the answer not in the manual?

Williams WBCF50 Specifications

General IconGeneral
BrandWilliams
ModelWBCF50
CategoryChiller
LanguageEnglish

Related product manuals