ENGLISH
17 (55)
8 Faults, Causes
Fault Unit-related Cause Unit-unrelated Cause
Pump does not start - defect printed circuit board
- defect diaphragm
- Power failure
- Pump capacity too low
- Pump mechanically jammed
- WILO-Fluidcontrol wrongly
connected
- Lack of water at suction side
Pump does not stop - defect printed circuit board
- jammed flow controller - stuck
reset button
- Pump does not generate sufficient
pressure
- Leakage loss greater than 0.6
l/min
Pump runs irregularly - defekt printed circuit board
- Pump does not generate sufficient
pressure (air)
- Leakage loss greater than 0.6
l/min
Pump is jammed - defect printed circuit board
- pump generates pressure < start
pressure
- defect diaphragm
- refer to Installation & Maintenance
Instr. of the pump
- Lack of water at suction side
- Pump capacity too low
If the fault cannot be located or rectified, please contact your nearest
Wilo representative.