EasyManua.ls Logo

Wilo Star RS Series - Troubleshooting; Motor Not Running; Noisy Operation; Spare Parts

Wilo Star RS Series
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
ENGLISH
8 Problems, Causes
and Remedies
Motor is switched on but fails to
run:
Check electrical fuses,
Check voltage of pump (observe
rating plate data),
Check capacitor size (observe
rating plate data!).
Motor is blocked, e.g. by deposits
from the heating water.
Remedies: Fully remove vent plug,
check and if necessary rectify free
running of pump rotor by turning
the slotted end of the shaft with a
screwdriver (Fig. 9).
At high water temperatures
and system pressure close
isolating valves before and
after the pump. First, allow
pump to cool down
Noisy pump operation
Cavitation due to insufficient inlet
pressure.
Remedies: increase system pressu-
re within the permissible range.
Check speed setting, if necessary
switch to a lower speed.
If the fault cannot be rectified,
contact your nearest WILO
Customer Service.
9 Spare parts
All rating plate data must be stated
when ordering spare parts.
Subject to technical alterations!