Installation and operating instructions Wilo-DrainLift Con 23
English
9.1 Cleaning the condensate collection reservoir
The inside of the condensate collection reservoir must be cleaned regularly.
Remove the condensate collection reservoir (Fig. 1, item 6) by pressing in the
clips (Fig. 1, item 3) and clean with a 5% bleach base solution.
Check the floater for dirt and, if necessary, clean with water or a 5% bleach base
solution.
Remount the condensate collection reservoir.
Perform a functional check (section 8.1).
9.2 Check the condensate drainage with the non-return valve
NOTE! Regularly check the non-return valve and the seal below it for dirt and
blockages.
Turn the non-return valve (Fig. 3, item 1) anti-clockwise and pull it off in an
upward direction.
Check the non-return valve for dirt and clean if necessary.
Check the seal (Fig. 3, item 2) for dirt and clean if necessary.
Place the seal in the connection of the non-return valve (Fig. 3, item 3).
Push the non-return valve down and turn it clockwise at the same time.
CAUTION! Risk of damage!
Never use aggressive cleaning agents or sharp-edged tools, as these could
damage the seal. Use only clean water to clean the seal of the non-return
valve.
Perform a functional check (section 8.1).