Warning
1. The UVC-Filter should be placed in such a way so that the water cannot reach
it. The distance between the pond’s edge and the filter should reach at least
2m. The UV lamp cannot be operated under water.
2. The power supply of the UVC-Filters must not be turned on before the water
circulation has been carried out.
3. Please position the UVC-Filter on a safe and stable place because the light
tube (the tube that conveys the light) of the pond filter is made of quartz glass
that can burn easily.
4. Do not turn the power on before all the component parts of the device are in-
stalled.
5. If the quartz glass tube or the upper part of the UVC-Filter is damaged, the
pond pressure filter cannot be used.
6. The UVC-Filter can also not be used if there are people in the pond water.
7. Make sure that the used voltage and the frequency correspond to those indi-
cated on the filter label.
8. When the device is installed you have to pay attention to the domestic installa-
tion rules.
9. Please do not pull on the connecting cord. Keep it away from heat, grease and
sharp objects.
10. Make sure the upper part of the filter is exposed to pressure lower than 0,3 bar.
11. In frosty weather please remove the UV-Filter.
12. When you install the UV-Filter do not expose it to direct sunlight.
13. Dirt influences the efficiency of the quartz glass tube; therefore it needs to be
regularly cleaned.
14. To secure the proper functioning of the device the UV-quartz tube should be
replaced after 8000 operating hours.
15. If the upper part is blocked by sand, the quartz tube can be destroyed. Please
place the filter sponge in the inlet of the water pump.
16. UV-light is harmful for the eyes and skin. Do not look directly into the UV-light
and do not expose your skin to it.
17. If you install the device or repair it, switch off the power supply of the lamp and
the pump.
18. The device must be installed on a horizontal flat surface with the feet down-
wards. For safety reasons it not allowed to install the device otherwise.