Maintenance
CAUTION
-
Always unplug machine at
mains outlet before dismantling any part
of machine.
If red light (A) shows, change paper filter bag.
To do this first pull cover release
(5)
picture
1
forward and lift the cover from the dust bag
housing. Slide the dust bag sealing plate (28)
from the holder (29). Slide the sealing plate (28)
of a new bag into the holder and push firmly in.
Insert cover into dust bag housing push is for
-
ward then lock
it
in place by pushing down the
cover release
(5).
The micro hygiene filter (30) needs to be
changed when it becomes clogged with dust
or after approximately 20 paper bags have
been used. To change the hygiene filter first
remove the cover then slide the filter out at the
bottom. To replace lift the lever and slide the
new filter in.
After 20 paper bags have been used also
change the exhaust filter (32). To remove the
exhaust filter push the catch (33) forward and
remove the filter cover (34) and filter.
Insert the new filter and replace the filter cover.
To change the brush roller (35) push the button
(36), remove the slide plate (37), turn the brush
clockwise a quarter of a turn and pull the brush
roller out. Slide the new brush roller into the
brush housing and turn it until it locates into
position. Push the button (36) and press the
side plate (37) back into place.
Underneath the machine is an inspection door
to check for blockages (38).
Blockages in the neck (20
-
picture
2)
can be
checked by first lifting
off
the dust bag housing
by pressing the catch (8). Then release the foot
pedal, lower the neck and check into the tube
next to the pedal.
Blockages in the hose can cleared by taking
the hose
off
the machine and replacing
it
the
wrong way round in the connecting tube (24)
holding it upright with one hand blocking the
top and switching on the machine.
(If necessary quickly lift your hand on and
off
the end of the hose).
The guarantee is invalidated
if
take out
parts not approved by
WINDSOR,
eg. bags,
filters, brush roller, etc., are
fmed!