EasyManua.ls Logo

WMF 10 - Troubleshooting Blockages

WMF 10
51 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Measures for problem recti cation
44
Problem Rectifi cation measure
The locking knob is blocked
and no coffee comes out
The opening in the middle of the pad cassette is blocked.
>Pull the mains plug and let the appliance cool for an hour.
If the blockage has still not dissolved there is an option of an emergency opening:
You need an of ce clip that has just been straightened for the purpose.
>Ensure that the end of the wire is free of burrs so that
the seal in the appliance is not damaged.
>Protect yourself from coffee that could get sprayed out of the appliance
that is possibly still hot. Touch the wire only with a dishcloth.
At the handle of the pad cassette, there are two small holes in the front.
>Guide the wire into the upper opening and then push it gently inwards.
After about 3 cm, the pressure will suddenly get released and some coffee
will escape. The blockage of the locking knob is thus removed.
>Remove the pad cassette and clean it thoroughly.
>Check each time before brewing, whether
- the opening in the centre of the pad cassette is clear,
- the pads are undamaged and
- the pad cassette is free of ground coffee residue.
GB