102
User Manual WMF1100 S
Messages and instructions | Errors without error message
Error pattern Action instructions
The milk foam dispensing
sputters severely
Milk too hot
Check whether the milk system has been
cleaned
Clean the milk system
w Care w Clean milk system manually, page 87
Check whether the milk has been cooled
sufficiently
Use the green milk nozzle
No powder beverage
dispensing
Clean the mixer bowl
Is the hose kinked?
Perform milk cleaning and rinsing more often,
ifnecessary daily
w Care w Cleaning intervals overview, page 74
w Care w Clean milk system manually, page 87
Use lower powder dosage
Use higher water dosage
The message “Empty drip
tray” is displayed, even
though the drip tray has
already been emptied.
The underside of the drip tray and the area around
the drip tray sensor must be dry before it is
inserted. The sensor is on the right, underneath the
drip tray. If there is residual moisture in this area,
the message, “Empty drip tray” appears again.
Pump runs continuously,
water in grounds
container
Switch the coffee machine off and on again
If error not remedied call WMFService