38
WMF 2000 S Service Manual Edition 11/2010
WMF 2000 S Service Manual
11.3.3 Service Maintenance 1 - Additional Choc
WMF 2000 S with Choc: Assembling maintenance set
additional Choc - every 6.000 Choc beverages
Note: Mixer meter counts choc beverages thrice; 6.000 choc
beverages correspond to a meter reading of 18.000
Add. maintenance set Choc/Topping 33.2828.6100
Nr. Description Order number Amount
Combi spout:
1 mixer hose 25 cm 00.0048.0064 25cm
2 hose connection 33.2269.1000 1
Valves:
3 valve 33.2273.9000 1
Mixer:
4 choc spout 33.2296.2000 1
5 angle piece (only bistro!) 33.2376.8000 1
6 mixer complete 33.2820.1000 1
11.3.4 Service-maintenance 2 years
Assembling service-maintenance 2 (MS 2) - every 2 years, does
not depend on the brewing capacity.
During service maintenance 2 the maintenance set 1 has to be
assembled additionally.
Maintenance set 2 WMF 2000 S - every 2 years
33.2853.7000
Nr. Description Order number Amount
Ventilation system:
1 fan compl. 33.1662.1200 1
2 drain hose 00.0048.0042 0,6m
3 cover 33.2474.7000 1
Boiler:
4 safety valve 16 bar 33.2297.0099 1
5 cable clip 33.0649.3000 1
6 hot water valve,
brewing valve,
Americano valve
33.2273.9000 3
Steam boiler:
7 safety valve 12 bar 33.2299.2099 1
8 cable clip 33.0649.3000 1
9 Cappuccino valve 33.2274.9000 1
Release valve:
10 release valve 33.2274.5000 1
CPU:
11 battery 33.2263.3000 1