12
GAS SUPPLY REQUIREMENTS
GAS MANIFOLD PRESSURE
F
or Natural Gas:
S
tandard orifices
are set for 5" (12.5 mb) WC (water column).
A natural gas pressure regulator is
i
ncluded.
For LP Gas:
Standard orifices are set for
10" (25 mb) WC (water column). An LP gas
pressure regulator is connected to the hose
provided with the grill.
Gas Supply Pressure:
For checking the
regulator setting, the maximum line
pressure for natural and LP gas: 14"
(34.9 mb) WC; .5 psi (3.5 kPa). Minimum
line pressure for natural gas: 7" (17.5 mb)
WC. Minimum line pressure for LP gas:
11" (27.4 mb) WC.
Gas Supply Regulator:
To control and
maintain a uniform gas pressure in the gas
manifold, the unit must be used with a gas
pressure regulator. The burner orifices, etc.
are sized for the gas pressure delivered by
the supplied regulator. Do not remove the
regulator.
The maximum gas supply pressure to
the regulator should never exceed 14"
(34.9 mb) WC; .5 psi (3.5 kPa).
LINE PRESSURE TESTING
T
esting above .5 psi (3.5 kPa) 14" (34.9 mb)
WC (gauge):
The BBQ grill and its individual
shut-off valve must be disconnected from the
g
as supply piping system during any pressure
testing of that system at test pressures greater
than .5 psi (3.5 kPa).
WOLF GAS BBQ GRILLS