Operating instructions
Gas red condensing boiler
CGB-11 Boiler
CGB-20 Boiler
CGB-24 Boiler
CGB-35 Boiler
CGB-50 Boiler
CGB-75 Boiler
CGB-100 Boiler
CGB-K-20 Combi boiler
CGB-K-24 Combi boiler
Wolf GmbH · Postfach 1380 · 84048 Mainburg · Tel. 08751/74-0 · Fax 08751/741600 · Internet: www.wolf-heiztechnik.de
Art.-Nr. 30 61 345 Salvo modiche 06/09 GB

Other manuals for Wolf CGB-35

Questions and Answers

  • W
    Wendy CarpenterAug 29, 2025
    Why is the LED constantly red on my Wolf CGB-35 Boiler?
    • B
      Brent MathewsAug 30, 2025
      If the LED is constantly red on your Wolf Boiler, it indicates that the ionization lead is shorted out or the ionization electrode is earthed (housing). Check the ionization lead and the position of the electrode to the burner. Press the reset button.
  • C
    Casey GainesAug 28, 2025
    What causes TBA excess temperature and positive pressure in Wolf CGB-35 Boiler?
    • D
      Dustin Garcia PhDAug 28, 2025
      If your Wolf Boiler displays a TBA excess temperature and positive pressure in the flue gas system, check for correct installation of the combustion chamber pot. Also, check the flue gas system and ventilation air system.
  • R
    Roberto RussellAug 27, 2025
    How to resolve DHW excess temperature in Wolf CGB-35 Boiler?
    • C
      Christopher ThomasAug 27, 2025
      If your Wolf Boiler shows a DHW excess temperature, check the system pressure and vent the heating system. Set the pump to stage 2 or 3.
  • R
    Richard BeckAug 27, 2025
    What causes a gas fan fault in a Wolf CGB-35?
    • N
      Nicole KimAug 27, 2025
      If the gas fan in your Wolf Boiler doesn't reach the required pre-purging speed, ignition speed or doesn't stop, check the gas fan supply cable and the gas fan itself. Then, press the reset button.
  • C
    Carla GlassAug 25, 2025
    Why does my Wolf CGB-35 show TBV excess temperature and low water pressure?
    • B
      brownvictoriaAug 26, 2025
      If your Wolf Boiler displays a TBV excess temperature and the water pressure is too low, check the system pressure and heating circuit pump. Also, check the HC pump step switch and vent the heating system. Press the reset button. Clean the heat exchanger and check the TB combustion chamber. Finally, increase system pressure.
  • D
    David ChoiAug 25, 2025
    What to do if Wolf CGB-35 flame fails during operation?
    • N
      Nathan JacobsonAug 25, 2025
      If your Wolf Boiler experiences flame failure within 15 seconds after flame recognition, check the CO values and inspect the ionization electrode and cable. Then, press the reset button.

Summary

Operating Instructions

Safety Instructions

Smelling Gas

Immediate actions to take if gas is detected, including ventilation and contacting services.

Smelling Flue Gas

Steps to follow if flue gas is detected, focusing on ventilation and contractor notification.

Changing a Fuse Safely

Procedure for safely changing a fuse, emphasizing power isolation to prevent electrocution.

Frost Protection Measures

Information on boiler protection against freezing, including operational status and draining.

Balanced Flue System Risks

Warning about ice formation on balanced flue pipes and potential injury or material loss.

Installation and Maintenance

Installation and Modifications

Guidance on boiler installation and modification by approved heating contractors only.

Care and Maintenance

Instructions for cleaning the boiler casing and importance of regular contractor maintenance.

Water Connections and Gas Supply

Filling the Heating System

Procedure for filling the heating system with water and checking pressure.

Wolf CGB-35 Specifications

General IconGeneral
TypeCondensing Boiler
Max. Heat Output35 kW
Max working pressure3 bar
Fuel TypeNatural Gas
Efficiency98%
Temperature range85°C