WOLF GMBH / POSTFACH 1380 / D-84048 MAINBURG / TEL. +49.0.875174-0 / FAX +49.0.875174-1600 / www.WOLF.eu
Art.-Nr. 3065081_201806
Änderungen vorbehalten /
Subject to modifications
Ölpumpe COB-20/29/40 - Einstellung Pumpendruck
Oil pump COB-20/29/40 - Setting pump pressure
Werkseinstellung Pumpendruck COB-20/29 /
factory setting pump pressure COB-20/29
ST 1 (Stufe 1/Stage 1) = 8,5 ± 1,0 bar
ST 2 (Stufe 2/Stage 2) = 16,8 ± 2,5 bar
Einstellung Pumpendruck COB-40 /
Setting pump pressure COB-40
COB-40 COB-29 COB-20 COB-15
ST1
ST2
ST1
ST2
SW 8
1½ x
½ x
SW 8
¼ x
¼ x
Pumpendruck /
Pump pressure
ST1
ST2
11,0 ± 1,0 bar
23,5 ± 2,5 bar
9,8 ± 1,0 bar
18,0 ± 2,5 bar
8,5 ± 1,0 bar
16,8 ± 2,5 bar
Kurzbedienungsanleitung -
Short operating instructions

Other manuals for Wolf COB-29

Questions and Answers

  • X
    xbrownSep 9, 2025
    How to fix faulty stratification sensor on Wolf Boiler?
    • D
      Daniel TownsendSep 9, 2025
      If the Wolf Boiler displays a faulty stratification sensor, it indicates a problem with the stratification cylinder sensor or its lead. Check the sensor and lead to resolve this.
  • M
    Melissa ButlerSep 12, 2025
    How to fix header sensor fault on Wolf COB-29?
    • C
      Christine CooperSep 12, 2025
      If the Wolf Boiler indicates a faulty header sensor, there is likely an issue with the sensor or its lead. Check the sensor and lead to troubleshoot.
  • R
    Robert PorterSep 12, 2025
    Why Wolf COB-29 Boiler has insufficient water pressure?
    • C
      Cassandra DavisSep 13, 2025
      If the Wolf Boiler displays insufficient water pressure, it's because the pressure switch isn't activating due to low water pressure (below 0.8 bar). Ensure the system pressure is above 1.5 bar, inspect the water pressure switch and its lead, and then press the reset button.
  • A
    Andrew SmithSep 15, 2025
    What to do if Wolf COB-29 Boiler condensate pump not pumping?
    • E
      Elizabeth DavisSep 15, 2025
      If the condensate pump in your Wolf Boiler is not pumping, it could be due to a defective pump, a blocked drain line, or a missing power supply. Check the pump itself, inspect the drain line for blockages, and verify the mains plug and fuse.
  • K
    Karen Mcknight PhDSep 16, 2025
    Why Wolf COB-29 Boiler has max cylinder heating time exceeded?
    • L
      Laura PearsonSep 16, 2025
      If the Wolf Boiler exceeds the maximum cylinder heating time, it means the set cylinder temperature hasn't been reached with sufficient flow. Try venting the cylinder, increasing the cylinder heating time (HG20), and checking the cylinder sensor installation.

Summary

Factory Setting Pump Pressure COB-20;29

Stage 1 Pressure Setting

Specifies the factory pressure setting for Stage 1 (ST 1) as 8.5 01.0 bar.

Stage 2 Pressure Setting

Specifies the factory pressure setting for Stage 2 (ST 2) as 16.8 02.5 bar.

Setting Pump Pressure for COB Models

COB-40 Pressure Adjustment Guide

Details adjustment method (SW 8, 1/2 X) and resulting ST1/ST2 pressures for COB-40.

COB-29 Pressure Adjustment Guide

Details adjustment method (SW 8, 1/4 X) and resulting ST1/ST2 pressures for COB-29.

COB-20 Pressure Adjustment Guide

Details adjustment method and resulting ST1/ST2 pressures for COB-20.

COB-15 Pressure Adjustment Guide

Details adjustment method and resulting ST1/ST2 pressures for COB-15.

Factory Setting Pump Pressure COB-2-20

Stage 1 Pressure Setting COB-2-20

Specifies the factory pressure setting for Stage 1 (ST 1) as 8.5 bar for COB-2-20.

Stage 2 Pressure Setting COB-2-20

Specifies the factory pressure setting for Stage 2 (ST 2) as 17 bar for COB-2-20.

Setting Pump Pressure for COB-2 Series Models

COB-2-40 Pressure Adjustment

Details adjustment method (1 X) and resulting ST1/ST2 pressures for COB-2-40.

COB-2-29 Pressure Adjustment

Details adjustment method (1/2 X, 3/4 X) and resulting ST1/ST2 pressures for COB-2-29.

COB-2-20 Pressure Adjustment

Details adjustment method (2 X 00 X) and resulting ST1/ST2 pressures for COB-2-20.

COB-2-15 Pressure Adjustment

Details adjustment method and resulting ST1/ST2 pressures for COB-2-15.

Wolf COB-29 Specifications

General IconGeneral
BrandWolf
ModelCOB-29
CategoryBoiler
LanguageEnglish

Related product manuals