Wolf Gas Cooktops 31
wolfappliance.com/specs
ELECTRICAL AND GAS REQUIREMENTS
Gas cooktops require a separate, grounded 220-240 V AC,
50/60 Hz power supply. The service should have a
grounded 3-prong receptacle located within reach of the
1.8 m power cord. Total amps for gas cooktops is less
than one.
A gas supply line of 19 mm rigid pipe must be provided to
the cooktop. If local codes permit, a certified, .9 m long,
13 mm or 19 mm ID flexible metal appliance connector is
recommended to connect the cooktop to the gas supply
line.
Wolf gas cooktops are designed to operate on natural gas
at 20 mb pressure or LP gas at 37 mb pressure.
Planning Information
F
or ease of installation, Wolf recommends using 838 mm
wide cabinets with 762 mm gas cooktops and 991 mm
cabinets with 914 mm cooktops.
Burner Rating kW kW
381 mm GAS COOKTOP HIGH SIMMER
Medium 3.8 .2
Small 3.0 .1
7
62 mm GAS COOKTOP HIGH SIMMER
Large 4.9 .2
Medium 3.8 .2
(2) Small 3.0 .1
914 mm GAS COOKTOP HIGH SIMMER
Large 4.9 .2
Medium 3.8 .2
(3) Small 3.0 .1