5
4.Water drainage
When the water reservoir is full, the
dehumidier is shut off automatically.
Once the water reservoir is emptied
the unit will automaticallt restart.
1. Disconnect the dehumidier from
the power source.
2. Empty the water reservoir.
3. Put the empty water reservoir back
and check that the oat moves
freely.
4. Connect the dehumidier to the
power source.
Direct water drainage
Connect a water hose (10mm) to
the pipe on the back of the dehu-
midier. Lead the other end to a
drain. Make sure that the water can
be drained downwards.
5. The air lter
The air lter prevents dust and dirt
from entering the machine, prolong-
ing its life expectancy. Please refer to
the separate lter leaet for installa-
tion and maintenance instructions.
1. Remove the lter.
2. Wash it with warm water and a
mild cleansing agent. Alternatively
the lter may be vacuum cleaned.
3. Let the lter dry and put it back.
It is very important that the
lter is cleaned regularly;
otherwise the dehumidier
might lose capacity and even
be seriously damaged.
6. Maintenance
- Clean the unit with a soft moist
cloth. Do not use solvents or strong
cleaners as this might damage the
surface of the unit.
- The front and side grids can be
vacuum-cleaned or cleaned with a
brush.
- The cooling coils are best cleaned
with a rag and warm water.
7. Service
If the dehumidier requires servicing,
you must rst contact your local retai-
ler. Proof of purchase is required for
all warranty claims.
8. Warranties
2 years product warranty. Please
note that the warranty is only valid
upon the production of the receipt.
This machine complies with EEC
directives 76/889 + 82/499
The unit is set to work between
+5ºC and + 32ºC.
If the temperature goes outside
this range the unit might not
work properly.
9. Hints
Sometimes it may be useful to use
a frost guard or heater fan to make
sure that the temperature does not
fall below +10˚C. Even if the MRD9
works down to temperatures as low
as +5°C, its capacity will increase
at higher temperatures as warm air
carries more water.
For maximum dehumidifying power
in a room, it is recommended that
the air supply from outside and from
adjoining rooms is minimized – close
doors and ventilators.
Expect higher dehumidication
capacity during Autumn / Summer
because the outside air is warmer
and more humid.
To achieve a safe and reliable pro-
tection against mould and moisture
damage, keep the relative humidity
between 50% and 60%.
English