Prepare for operation
9
Greenstar 4000 – 6 720 891 170 (2020/09)
Fig. 7 Keyed filling link
External filling loop
Once the external filling loop and pressure menu has been located,
follow the instructions for re-pressurising the system.
Refer to figure 8.
Unscrew the blanking cap [1].
Attach the hose [2] to the valve.
Usually one end of the hose is already connected to one of the
system fill isolation valves.
Ensure both ends [3] of the hose are screwed on hand tight.
Monitor the pressure menu.
The system fill isolation valves [4] are in a closed position (the
handle/screwdriver slot is across the valve).
Turn the handle/screwdriver slot through 90° to open valves and
slowly fill the system.
The system fill isolation valves [5] are opened (the handle/
screwdriver slot is in-line with the valve).
The pressure menu indicator moves and the displayed message
may change [6].
Turn the handles/screwdriver slots back, through 90°, to close the
valves when the:
The pressure menu reads OK and the pressure menu indicator is
in the green zone [8] .
The system fill isolation valves [7] are in a closed position (the
handle/screwdriver slot is across the valve).
Top up the system pressure, if as a result of the air bleeding the
pressure drops off.
Remove the hose [2] and replace the blanking cap [1].
Fig. 8 External filling loop
If the pressure gauge reads more than 1.7 bar as a result of over filling:
Bleed one radiator until the pressure gauge returns to between 1 and
1.7 bar.
It is good practice to bleed any excess air that has entered the heating
system due to pressure loss. Locate and open the radiator's bleed/
vent point, closing the valve when water begins to flow.
If, through normal boiler operation, the PRV pipe starts to leak, it
could be a sign of system pressure being too high. In this instance
please bleed a radiator as described above.
6
6
2
1
4
4
3
3
4
3
3
1
Fault - 1017
Pressure: 0.7 bar
System pressure
too low
5
Pressure OK: 1.7 bar
System pressure ok.
Stop refilling
7
0010033764-001
Pressure OK: 1.5 bar
System pressure ok.
Stop refilling
Fault - 1017
Pressure: 0.6 bar
System pressure
too low
1
2
3
4
5
7
0010033763-001
68