LAYOUT & COMPONENTS
LAYOUT & COMPONENTS
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR 24 i junior/28 i junior
8 716 115 166b (03/2009)
8
APPLIANCE
INFORMATION
14 SYSTEM PRESSURE GAUGE
15 SYSTEM PUMP
26 PLATE TO P LATE DHW HEAT
EXCHANGER
33 FLOW TURBINE
34 COMPACT HYDRAULIC MOUNTING
SCREW (2) TO BOILER
35 PRESSURE RELIEF VALVE
36 DIVERTER VALVE
37 CH RETURN CONNECTION TO SERVICE
VALVE
38 DRAIN TAP
39 COLD WATER IN CONNECTION
40 INTERNAL BYPASS WITHIN PLASTIC
MOULDING
41 DHW OUT CONNECTION
42 CH FLOW CONNECTION TO SERVICE
VALVE
43 DHW SENSOR
44 FLOW CONNECTION FROM BOILER
HEAT EXCHANGER
45 AUTO AIR VENT
46 UNUSED PORT
47 FAULT RESET BUTTON
48 ECO BUTTON
49 MAINS ON/OFF INDICATOR/
DIAGNOSTIC LIGHT (BLUE)
50 CH TEMPERATURE CONTROL
51 POSITION FOR OPTIONAL
PROGRAMMER
52 SERVICE MODE BUTTON
53 BURNER ON INDICATOR LIGHT (GREEN)
54 MASTER SWITCH ON/OFF