EasyManua.ls Logo

Worcester Greenstar Danesmoor Utility Regular ErP 25/32

Worcester Greenstar Danesmoor Utility Regular ErP 25/32
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Installation, Commissioning and Servicing instruction manual
Floor Standing oil-fired Condensing Boiler Conventional Flue & Room Sealed Flue
Greenstar Danesmoor Utility Regular
ErP
& Utility System
ErP
12/18, 18/25, & 25/32
6720809436-00.1Wo
For fully pumped open vent or sealed central heating systems and domestic hot water cylinders
These appliances are for use with Kerosene (Class C2) only.
6 720 813 286 (2014/09)

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Worcester Greenstar Danesmoor Utility Regular ErP 25/32 and is the answer not in the manual?

Worcester Greenstar Danesmoor Utility Regular ErP 25/32 Specifications

General IconGeneral
ModelGreenstar Danesmoor Utility Regular ErP 25/32
CategoryBoiler
Fuel TypeOil
ErP RatingA
Installation TypeFloor Standing
Dimensions (HxWxD)855 x 370 x 600 mm
Warranty2 years
Output Rating25-32 kW

Summary

Key to symbols and safety instructions

Key to symbols

Explains warning symbols, hazard keywords, and important information indicators.

General safety instructions

Covers essential safety practices for installation engineers and users.

Installation, commissioning and servicing

Emphasizes that these tasks must be performed by qualified registered engineers.

Electrical work

Details requirements for qualified electricians performing electrical tasks on the appliance.

Installation regulations

Complying with the building regulations

Details requirements for compliance with building codes, standards, and regulations.

Appliance information

Technical data

Lists key technical specifications for central heating, flue, and electrical systems.

Pre-Installation

Cleaning primary systems

Instructions for flushing and cleaning the primary heating system before installation.

Oil supply

Details requirements for the kerosene oil supply system.

Condensate pipework

Instructions for installing condensate drainage pipework.

Boiler locations and clearances

Specifies suitable locations and required clearances for the boiler.

Flue terminal positions

Guidelines for positioning flue terminals to avoid combustion product entry.

Installation

Oil burner and pump

Instructions for installing and connecting the oil burner and pump.

Commissioning

Pre-Commissioning checks - 1825 Regular shown

Checks to be performed before starting the commissioning process.

Starting the appliance

Steps for safely starting the boiler after installation.

Service and Spares

Inspection and service - 1825 Regular shown

Guidance for performing routine inspection and service on the boiler.

Fault finding and diagnosis

Burner functions

Troubleshooting guide for burner operational faults.

Heating and hot water

Troubleshooting guide for heating and hot water system issues.

Boiler function

Troubleshooting guide for general boiler operational faults.

Logic for the 535 SELD RDB control box

Diagnostic logic chart for the 535 SE/LD RDB control box.