Appliance information
Greenstar Danesmoor Utility
ErP
and Utility System
ErP
- 6 720 813 286 (2014/09) 7
3.3 Energy efficiency
The following product data satisfy the requirements of the EU Regulations No. 811/2013 and No. 812/2013 supplementing Directive 2010/30/EU.
Product data Symbol Unit 7731600056 7731600057 7731600058 7731600065 7731600066 7731600067
Product type Danesmoor
Utility Regular
ErP
12/18
Danesmoor
Utility Regular
ErP
18/25
Danesmoor
Utility Regular
ErP
25/32
Danesmoor
Utility System
ErP
12/18
Danesmoor
Utility System
ErP
18/25
Danesmoor
Utility System
ErP
25/32
Condensing boiler Yes Yes Yes Yes Yes Yes
Low temperature boiler No No No No No No
B1 boiler No No No No No No
Cogeneration space heater
(CHP)
No No No No No No
Combination heater No No No No No No
Rated heat output P
rated
kW 18 25 32 18 25 32
Seasonal space heating
energy efficiency
η
s
% 919091919091
Energy efficiency class–AAAAAA
Useful heat output
At rated heat output and
high temperature regime
1)
1) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
P
4
kW 17.9 24.9 32.2 17.9 24.9 32.2
At 30 % of rated heat output
and low temperature regime
2)
2) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet).
P
1
kW 5.7 7.9 10.2 5.7 7.9 10.2
Useful efficiency
At rated heat output and
high temperature regime
1)
η
4
% 91.1 90.9 91.4 91.1 90.9 91.4
At 30 % of rated heat output
and low temperature regime
2)
η
1
% 96.8 95.8 96 96.8 95.8 96
Auxiliary electricity consumption
At full load el
max
kW 0.143 0.16 0.16 0.143 0.16 0.16
At part load el
min
kW 0.043 0.048 0.048 0.043 0.048 0.048
In standby mode P
SB
kW000000
Other items
Standby heat loss P
stby
kW 0.123 0.16 0.16 0.123 0.123 0.16
Ignition burner power
consumption
P
ign
kW------
Emissions of nitrogen
oxides
NOx mg/kWh 243 193 136 243 193 136
Annual energy consumption Q
HE
kWh------
Sound power level, indoors L
WA
dB(A)535456555555
Table 2 Product data for energy consumption