Shutdown
Greenstar 8000 + – 6721890764 (2024/06)
10
6Shutdown
6.1 Setting frost protection
NOTICE
Risk of damage to the system from frost!
The heating system can freeze up after a prolonged period (e.g. during a
power failure, switching off the power supply, faulty fuel supply, boiler
fault etc.).
Ā Ensure that the heating system is in constant use (particularly when
there is a risk of frost).
If you are leaving your property unoccupied during cold weather, please
leave your external programmer on constant and your room thermostat
set to 12 °C.
7 Thermal disinfection
To prevent hot water from becoming contaminated by bacteria such as
legionella, we recommend thermal disinfection after long downtimes.
CAUTION
Risk of scalding.
During thermal disinfection, discharging unmixed hot water can cause
serious scalding.
Ā Only use the maximum adjustable hot water temperature for thermal
disinfection.
Ā Inform occupants of the premises of the risk of scalding.
Ā Perform thermal disinfection outside of the normal operating times.
Ā Do not discharge DHW unmixed.
Proper thermal disinfection involves the DHW system including the
draw-off points.
Ā Set the thermal disinfection in the hot water program of the heating
controller (Æ heating controller operating instructions).
Ā Close DHW draw-off points.
Ā Set any DHW circulation pump to continuous operation.
Ā Wait until the maximum temperature is reached.
Ā Open all DHW draw-off points, from the nearest to the one furthest
away, and draw off hot water until hot water at a minimum of 70 °C
has flown from all draw-off points for at least 3 minutes.
Ā Restore the original settings.
8 Clearances and ventilation information
8.1 Appliance clearances
Your installer will have provided adequate space around the appliance
for operation, safety and servicing/maintenance access.
• The following detail the necessary clearance around the appliance for
service and maintenance.
CAUTION
Risk of damage to appliance or property
The appliance will overheat if the clearance space around the appliance
is restricted by objects.
Ā Do not restrict this space with the addition of cupboards, shelves etc.
next to or around the appliance.
Ā Do not store any combustible materials on or next to the appliance,
such as clothes, towels, paper or plastic bags.
Fig. 7 Appliance minimum clearances
Table 6
[*] Height for either 60/100 flue or 80/125 flue
8.2 Ventilation information
The air supply must not be restricted or contaminated.
Ventilation considerations
Ā Do not place objects to hinder the air circulation required by the
appliance.
Ā The installation premises may require ventilation to be fitted
according to its features or use.
Minimum clearances
Description Dimensions [mm]
X Appliance width 440
Y Appliance height 780
Z Appliance depth 365
Installation/Maintenance
1 Overall clearance height 1,150/1,190*
2 Overall clearance depth 965
3 In front of appliance 450
4 Overall clearance width 450
5 Above the appliance 170/210*
6 Either side of appliance 5
7 Below the appliance 200
8 Compartment depth 385
9 Appliance to removable door 20
10 Min clearance to the floor 400
0010012940-002