Fault finding and diagnosis
Greenstar i System
ErP
- 6 720 806 945 (2015/07)
67
Gas valve fault FA 306 Ionisation detected after the gas valve
closed.
Inspect the ionization probe, replace if necessary.
Check that the condensate is discharging.
Check 230Vac across blue & orange wires to the coils.
Replace gas valve if no voltage.
Replace control box if there is voltage.
Ignition/Ionisation fault EA 227 No ionisation detected after ignition ▶Check:
The dynamic gas pressure.
The flue system for restrictions.
The gas-air ratio (if possible).
Connectors of the ignition unit.
Ignition and ionisation current.
Ignition unit for damage or wear, replace if
necessary.
Gas valve operation.
Appliance for contamination.
Ignition/Ionisation fault F7 228 Ionisation current detected before burner-
start
▶Check:
Condition of the ionisation probe.
Connection of the ionisation probe.
Condensate is discharging correctly.
Replace parts if necessary.
Ignition/Ionisation fault EA 229 Loss of ionisation signal during operation ▶Check:
The gas-air ratio.
–The dynamic gas.
Wiring and connection of flame probe.
Replace flame probe necessary.
Ignition/Ionisation fault EA 261 HCM potentially defective Reset the appliance.
If continues to go to this error
▶Check:
HCM is inserted properly.
–HCM number.
Contact technical helpline.
Internal error 9U 233 Control box or HCM is defective or loose ▶Check:
HCM is inserted properly.
Replace HCM if necessary.
Connections of the control box.
Replace control box if necessary.
Internal error C4 237 Control box or the HCM is defective. ▶Check:
HCM is inserted properly.
Replace HCM if necessary.
Connections of the control box.
Replace control box if necessary.
Internal error F0 238 Gas valve or control box error ▶Check:
–Gas valve coils:
230V ac across blue & orange wires.
Replace gas valve if necessary.
Connections of the control box.
Replace control box if necessary.
Internal error F0 239 Control box or the HCM is defective. ▶Check:
HCM is inserted properly.
Replace HCM if necessary.
Connections of the control box.
Replace control box if necessary.
Internal error F0 242 -
256
Control box or the HCM is defective. ▶Check:
HCM is inserted properly.
Connections of the control box.
Contact technical helpline.
Display text
Fault
code
Cause
code
Description Possible solution/check
Table 49

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester Greenstar i System ErP Series and is the answer not in the manual?

Worcester Greenstar i System ErP Series Specifications

General IconGeneral
BrandWorcester
ModelGreenstar i System ErP Series
CategoryBoiler
LanguageEnglish

Related product manuals