16
Safety informaon/Technical data
Operang pressure vessels
• You must keep your pressure vessel in good working order, operate the vessel
correctly, monitor the vessel, carry out necessary maintenance and repair work
immediately and meet the relevant safety precauons.
• The supervisory authority may enforce essenal control measures in individual
cases.
• A pressure vessel is not allowed to be used if it has faults or deciencies that can
endanger workers or third pares.
• Check the pressure vessel for signs of rust and damage each me before using.
Do not use the compressor with a damaged or rusty pressure vessel.
If you discover any damage, then please contact the customer service workshop.
DO NOT LOSE THESE SAFETY INSTRUCTIONS
6. Technical data
Mains connecon 230-240 V ~ 50 Hz
Motor rang W 1800
Operang mode S1
Compressor speed 2850 min
-1
Pressure vessel capacity (in liters) 50
Operang pressure approx. 10 bar
Theorecal intake capacity (l/min) approx. 271
Sound power level L
WA
97 dB(A)
Uncertainty K
WA
2.42 dB
Protecon type IP20
Weight of the unit in kg approx. 32
Oil (15W 40) l approx. 0.25
Max. Altude (above mean sea level) 1000 m
The noise emission values were measured in accordance with EN ISO 3744.
Wear hearing protecon
The eects of noise can cause a loss of hearing.