EasyManua.ls Logo

WORKZONE TITANIUM PREMIUM HC520 - 6. Technical Data; Technical Specifications

WORKZONE TITANIUM PREMIUM HC520
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
Safety informaon/Technical data
Operang pressure vessels
You must keep your pressure vessel in good working order, operate the vessel
correctly, monitor the vessel, carry out necessary maintenance and repair work
immediately and meet the relevant safety precauons.
The supervisory authority may enforce essenal control measures in individual
cases.
A pressure vessel is not allowed to be used if it has faults or deciencies that can
endanger workers or third pares.
Check the pressure vessel for signs of rust and damage each me before using.
Do not use the compressor with a damaged or rusty pressure vessel.
If you discover any damage, then please contact the customer service workshop.
DO NOT LOSE THESE SAFETY INSTRUCTIONS
6. Technical data
Mains connecon 230-240 V ~ 50 Hz
Motor rang W 1800
Operang mode S1
Compressor speed 2850 min
-1
Pressure vessel capacity (in liters) 50
Operang pressure approx. 10 bar
Theorecal intake capacity (l/min) approx. 271
Sound power level L
WA
97 dB(A)
Uncertainty K
WA
2.42 dB
Protecon type IP20
Weight of the unit in kg approx. 32
Oil (15W 40) l approx. 0.25
Max. Altude (above mean sea level) 1000 m
The noise emission values were measured in accordance with EN ISO 3744.
Wear hearing protecon
The eects of noise can cause a loss of hearing.