Before starng the equipment/Assembling and operaon
7. Before starng the equipment
m Aenon!
Before you connect the equipment to the mains supply make sure that the data on
the rang plate are idencal to the mains data.
Check the equipment for damage which may have occurred in transit. Report any
damage immediately to the transport company which was used to deliver the
compressor.
Install the compressor near the point of consumpon.
Avoid long air lines and supply lines (extension cables).
Make sure that the intake air is dry and dusree.
Do not install the compressor in a damp or wet room.
The compressor may only be used in suitable rooms (with good venlaon and an
ambient temperature from +5 °C to 40 °C). There must be no dust, acids, vapors,
explosive gases or inammable gases in the room.
The compressor is designed to be used in dry rooms. It is prohibited to use the
compressor in areas where work is conducted with sprayed water.
The oil level in the compressor pump has to be checked before pung the
equipment into operaon.
8. Assembling and operaon
m Warning!
Prior to any adjustment work disconnect the mains power plug!
m Important!
You must fully assemble the appliance before using it for the rst me!
You will require the following tools for assembly and installaon: 2 x open-ended
wrench size 17 mm (not included)
8.1 Fing the wheels (Fig. 5)
Fit the supplied wheels as shown.
8.2 Fing the supporng foot (Fig. 6)
Fit the supplied supporng foot as shown.
8.3 Fing the air lter (Fig. 7/8)
Remove the transportaon stop (B) and screw the air lter (15) to the equipment.