Troubleshooting
Make sure your Off limits module is securely installed and follow the actions below if your Landroid
®
does not operate correctly.
If these do not identify and correct the problem, please go to https://account.worxlandroid.com/, access your profile and open a
ticket using the form.
Symptom Cause Action
Landroid
®
fails to recognize the
magnetic strip and goes across it.
The magnetic strip loop is not closed.
Every piece of magnetic strip inside the
connector should be no shorter than 20mm.
The connector is not well joined.
Check and make sure the connector is well
joined.
The magnetic strip is buried too deep
under ground, in a hole or under the
concrete.
Reposition the magnetic strip to lie flat on the
ground.
The magnetic strip is not working as
temperature is too high (more than 65°C)
Wait until the temperature cools down.
Landroid
®
stops near the magnetic
strip
Landroid
®
is trapped after bumping into
the magnetic strip several times.
1. Turn Landroid off and take it to an area free
of obstacles.
2. Check strip layout.
3. Turn Landroid
®
on. Press START and OK.
Landroid
®
runs round near the
ring-fence area.
The magnetic strip is too close to the
boundary wire.
Two ring-fence areas are too close to
each other.
Keep a space of at least 2m between the
boundary wire and the magnetic strip or
between two ring-fence areas.
The magnetic strip is overlapping the
boundary wire.
The magnetic strip should be kept 2m away
from the boundary wire.
Some interference may exist in the
working area, due to electric cables or
iron pieces underground.
Check and remove interference.
Landroid
®
enters into the ring-
fence area.
Landroid
®
slips when it draws back
and makes a turn after recognizing the
magnetic strip.
Avoid lying the magnetic strip in areas where
Landroid
®
can slip (eg. areas with slopes).