3. Specifications
Specifications table:
Current: 0 – 100 A
(CONTINUOUS)
,200 A
(PEAK)
Battery voltage: 0 – 45 VDC
Supply voltage: 4,5 – 6 VDC
Supply current: 70 mA max
Measured energy: 0 - 38000 Wh
Energy resolution: 0,1 Wh
Energy accuracy +/- 1 % for current above 5 A
Sampling frequency 50 Hz
Starting current threshold I
S
: 0 – 5 A
Ramp time t
R
: 0 - 30 s
Throttle minimum Th
MIN
: 0 - 99 %
Limit time t
L
: 0 - 999 s
Minimum Pulse width t
PWM
: 0,8 - 1,6 ms
Series resistance: 0,0001 Ω
Connection cable:
AWG 10 (5,3 mm
2
)
Display: 3 digit, LED
Dimensions (without cables): 45x31x12 mm
Weight: 35 g
Nominal Operating Conditions: 0 – 50 ºC ambient temperature, IP67