17
When the test is completed, the display shows the actual volts and the actual
CCA or %. Press the ◄/► key to select SOH (state of health) or SOC (state of
charge). One of six results will be displayed:
GOOD & PASS
××.××V ×××× SAE
Good & pass
The battery is OK and can receive electricity.
GOOD & RECHARGE
××.××V ×××× SAE
Good & Recharge
The battery is OK but needs to be recharged.
RECHARGE & RETEST
××.××V ×××× SAE
Recharge & retest
Battery is discharged, the battery condition cannot be determined until it is fully
charged. Recharge the battery & test it again.
BAD & REPLACE
××.××V ×××× SAE
Bad & Replace
The battery will not hold a charge. It should be replaced immediately.
BAD CELL & REPLACE
××.××V ×××× SAE
Cell defective
The battery has at least one cell short circuit. It should be replaced immediately.
LOAD ERROR
Load Error
The tested battery is bigger than 2000 CCA or 200 AH. Or the clamps are not
connected properly. Please charge the battery completely and test it again after
both options could be excluded. If the same test result is shown, replace the
battery immediately.
PRINT RESULT? ◄ ►
NO
Press the ◄ ► key to select whether the result is to be printed: Yes or No. Con-
rm with Enter.
PRINT 24V SYSTEM
RESULT? YES
* Printing the 24V system test: The printer will not print the result of the 24 Volt
batteries system test. The 24V system test result will be recorded till you hook up
to a 12V battery. Then the screen on the left shows up. Select Yes and press
the Enter key to print the result. Then disconnect the terminals. The screen will
appear again after you reconnect the terminals. Select No and press the Enter
key to return to the main menu.
Press the Enter key to get to the initial battery test menu or remove the test termi-
nals from the battery to switch o the device.