The compressor fails to start.
The pressure switch 7 is actuated. > Wait a short while. Press the re-starting switch
and press the On/Off switch 1 to switch on the
compressor. If the motor protection is actuated
again, contact the customer service.
The manometer 14 shows a pressure greater
than 7.5 bar (for the K 200 5 bar) (cutting-in
pressure).
> Release pressure until the pressure switch 7
switches on.
Mains voltage fails. > Check the electrical leads, etc.
Compressor runs uninterruptedly.
Intake filter 4 is dirty. > Clean filter or replace.
The compressor is overloaded. > Reduce the compressed air requirement.
Leakage in the subsequent lead system. > Eliminate leakage.
Compressor is defective. > Contact the customer service.
The compressor runs for a short time when reaching the cutting-in pressure but then automatically
switches off.
The compressor was not de-pressurised because
the electrical feed was interrupted during opera-
tion.
> Switch the compressor off using the On/Off
switch 1 and then switch it on again.
On/Off switch 1 is defective. > Contact the customer service.
The length of the mains connection lead is not
permissible or the conducting cross-section is too
small.
> Lead length max. 25 m with a cross-section of
1.5 mm
2
.
At standstill, compressed air escapes for a longer period through relief valve 6 under pressure switch 7,
until the cutting-in pressure is reached.
Non-return valve 15 has a leak or is defective. > Contact the customer service.
During operation compressed air escapes through relief valve 6.
Relief valve 6 has a leak. > Contact customer service.
Compressor often switches on.
Condensation water in the compressed air reser-
voir 16.
> Drain condensation water.
Compressor is overloaded. > Reduce compressed air requirement.
Reduced performance due to worn valve plate. > Contact customer service.
Safety valve 13 blows off.
Reservoir pressure is greater than the opening
pressure of the safety valve 13.
Pressure switch 7 must be re-set or changed;
contact customer service.