Why won't my Würth Measuring Instruments RL 5-14 turn on?
- MManuel LaraAug 3, 2025
If your Würth Measuring Instruments RL 5-14 does not turn on, the batteries may be low or dead. Check the batteries and replace or charge them if needed.
Why won't my Würth Measuring Instruments RL 5-14 turn on?
If your Würth Measuring Instruments RL 5-14 does not turn on, the batteries may be low or dead. Check the batteries and replace or charge them if needed.
What to do if the laser receiver is not working properly with Würth RL 5-14?
If the laser receiver isn't working properly with your Würth Measuring Instruments, the RL 5-14 might not be rotating because it's levelling or in Elevation Alert. Ensure the RL 5-14 is operating correctly. Also, the receiver could be out of usable range; try moving closer to the RL 5-14. Lastly, check the receiver's batteries and replace them if they are low.
How to fix Würth Measuring Instruments RL 5-14 when it is working, but not self-levelling?
If the Würth Measuring Instruments RL 5-14 is working but not self-levelling, it might be in Manual Mode. To enable self-levelling, set the RL 5-14 to Automatic Mode by pressing the Automatic/Manual Mode button. When in Automatic Mode, the X-axis LED and the Y-axis LED will flash green while levelling. In Manual Mode, the X-axis LED and/or the Y-axis LED will be red.
Why is the laser distance reduced on my Würth Measuring Instruments?
If the distance of the laser is reduced on your Würth Measuring Instruments RL 5-14, dirt may be reducing the laser output. Clean the windows of the RL 5-14 and the receiver.
How to enable Elevation Alert function on Würth Measuring Instruments?
If the Elevation Alert function is not working on your Würth Measuring Instruments RL 5-14, it might be disabled. To enable or disable the Elevation Alert function, turn on the RL 5-14 and ensure it is rotating. Then, press and hold the Left and Right Arrow buttons, and press the Automatic/Manual Mode button. The RL 5-14 will beep once to indicate the change.
What to do if Würth Measuring Instruments RL 5-14 cannot communicate with the RC 5-14 Remote Control?
If the Würth Measuring Instruments RL 5-14 cannot communicate with the RC 5-14 Remote Control, it may be because the two devices have not been paired. You need to pair the RL 5-14 and the remote.
Brand | Würth |
---|---|
Model | RL 5-14 |
Category | Measuring Instruments |
Language | English |
Covers general directions to avoid hazards and understand warning messages.
Details the product's intended applications and foreseeable misuse.
Outlines risks like electrocution, lightning, and necessary safety measures.
Provides step-by-step instructions for setting up the RL 5-14 on a tripod.
Explains the purpose and operation of each button on the RL 5-14.
Details switching axes to manual mode and entering slopes using buttons.
Step-by-step guide for charging the rechargeable Li-Ion battery pack.
Step-by-step procedure to verify the level accuracy of the laser.
Instructions on how to adjust the laser's level accuracy using the device controls.
Detailed steps for adjusting the X, Y, and Z axes of the laser.
Explains alert symbols, symptoms, and their possible causes and solutions.
Addresses common issues like non-levelling, power failures, and reduced laser output.
Key technical data including operating range, self-levelling accuracy, and laser diode type.